Securely fix cement particle board to the
steel frame, ensuring that manufacturers instructions are closely followed
for fixing types, fixing pattern, joint widths etc.
Seal all board joints with WBS silicone
sealant.
Mechanically fix the EPSITEC cavity
spacer track at a maximum of 600mm vertical centres, with approved mechanical
fixings.
NB: extra track will be required around window and door
openings.
Mechanically fix drainage deflector
beads and cavity intumescent closer strips (fire stops) at specified positions,
using approved mechanical fixings.
Mechanically fix insulation boards
onto spacer track, using a staggered bonding pattern, ensuring that all
vertical board joints align with the spacer track.
Mix basecoat to a pliable consistency
and trowel apply initial coat to insulation boards at a thickness of 4-5mm.
Bed in alkali resistant reinforcing
mesh into top third of basecoat, ensuring that an overlap of 75mm is achieved.
Apply additional stress patches and corner reinforcements across all window
and door openings at 45° angles.
When basecoat is set, apply an additional
layer of basecoat and smooth out with a damp dry lining sponge.
Apply WBS primer (colour to match
final texture coat) in accordance with manufacturer’s instructions.
Thoroughly mix the WBS Silicone texture
finish to a uniform consistency.
Apply in a
continuous motion always working to a wet edge.
|